HOW TO SIZE SURGE PROTECTION DEVICES EXPERT GUIDE

How large a surge protection module should the distribution box be equipped with

How large a surge protection module should the distribution box be equipped with

Therefore, it is recommended practice that both the input circuit to the UPS and the associated UPS bypass circuits (including the manual maintenance bypass circuit) be equipped with effective Category "B" surge protective device, as specified in IEEE Std. SPD enclosures must be compatible with the target distribution box or panelboard layout, whether it's a surface-mounted load center or a flush-mounted industrial cabinet. For all other cases SPDs shall be fitted to protect against transient overvoltages, unless the owner of the installation declines such protection and wishes to accept the risk of damage to both wiring and equipment as tolerable. When installing a surge suppressor, it is important to mount it as close to the electrical equipment as possible in order to keep the wiring (lead length) between the electrical equipment and the suppressor as short as possible. At the incoming distribution box, if the main air circuit breaker is greater than 630 A or MCCB is between 315 A and 630 A, the upstream dedicated disconnector of SPD should use a 200 A circuit breaker or a 250~315 A fuse.

Read More
Integrated relay protection devices should be used every 4 years

Integrated relay protection devices should be used every 4 years

A general rule of thumb would be to visually inspect every one to two years, secondary injection testing every one to three years, and primary injection every three to five years or on major changes. This document also directs personnel to follow the utility procedures in the Protective Equipment Standard Test Procedures (PESTP) Manual and the. They were talking about doing away with full testing on microprocessor based relays. Protective relays and devices have been developed over 100 years ago to provide "lastline"of defense for the electrical systems. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. Outdated electrical protection increases fire risk, downtime, and liability, requiring timely upgrades.

Read More
Operating Methods of Relay Protection Devices

Operating Methods of Relay Protection Devices

Unlike switching type electromechanical with fixed and usually ill-defined operating voltage thresholds and operating times, protective relays have well-established, selectable, and adjustable time and current (or other operating parameter) operating characteristics. Protection relays may use arrays of, shaded-pole, magnets, operating and restraint coils, solenoid-type operators, telephone-relay contacts.

Read More
How often should relay protection be calibrated

How often should relay protection be calibrated

110 (4), ER (Electricity Regulations) 1994; any protective relay and device of an installation will need to be checked, tested and calibrated by a competent person at least once every two years, or at any time as directed by the Energy Commission. When a relay malfunctions or fails, the costs can be severe: equipment damage, safety threats, and even prolonged power outages. This guide is designed to inform engineers, power system operators, and technical enthusiasts about the calibration process, its importance for different relay types, and best practices based on. Most IED SW has a way to compare the settings that should be in the relay with the settings that are in the relay. This causes the relay to open the main Switch (called a Circuit Breaker) when the current goes high.

Read More