GPC GOV PUBLIC PROCUREMENT MONITORING IN BELGIUM

Power Supply for Monitoring Fiber Optic Cables

Power Supply for Monitoring Fiber Optic Cables

By listening to acoustic indicators of functional performance, this system provides on-line, cost-effective power cable condition monitoring at each point along the entire asset. Monitor ground strain, temperature changesand shock waves in order to detect and locate short circuits in real-time, with +/- 10m accuracy. Detect, locate and classify potential third party interference (TPI) events, such as manual or mechanical excavation and theft. Benefit from fast, reliable, on-line notifications that pinpoint damaged areas for rapid dispatch, investigation and repairs.

Read More
Dimensional parameters of corrugated ducts for monitoring

Dimensional parameters of corrugated ducts for monitoring

EN 61386 stipulates the dimensions of corrugated pipes: measurements, internal and external diameters. Cable manufacturers, on the other hand, define the length of coils and bars and their packaging. Factory pre-installed Bull-LineTM Pull Tape with EVEN-LOADTM, ensures extra slack at any access point throughout the reel. Comes standard on 2"; is available for 1"-1 1/2" CONDUIT MARKINGS Permanent marking along conduit includes: material. The semi-rigid hot-dipped galvanized metal duct is strong and durable for casting into concrete and is easily tied into position adjacent to reinforcing steel.

Read More
Insulation Requirements for Monitoring Distribution Boxes

Insulation Requirements for Monitoring Distribution Boxes

This part of IEC 61557 specifies the requirements for insulation monitoring devices (IMD) which permanently monitor the insulation resistance R F to earth of unearthed a. Among all the protection methods identified by the Standard, only IT distribution systems can guarantee greater operational continuity in case of a first fault to earth: in these systems, the circuit-breaker will not trip because the fault current is limited by the high insulation impedance. It is intended to give an alert (light and sound) or disconnect the power supply when the resistance between the two conductors drops below a set value, usually 50 k Ω (sample of IEC standard. The devices recognize insulation faults as they develop, tripping as soon as the value falls below minimum set thresholds.

Read More

Get In Touch

Connect With Us

📱

Spain (Sales & Engineering HQ)

+34 910 257 483

🇪🇺

Germany (EU Technical Support)

+49 30 983 217 46

📍

Headquarters & Manufacturing

Calle de la Innovación 22, 28043 Madrid, Spain